bind-internal: allow admin workstation + router to query authoritative (#258)
## Why Allow the operator's workstation and router to query the bind-authoritative servers directly. Their source addresses are outside the existing `auth-acl-main` client subnets, so named returns REFUSED to them today. The router sits on 198.18.21.0/24 which is not in the ACL at all. ## Changes - Add `10.10.12.200/32` (workstation, over wireguard) to `auth-acl-main` - Add `198.18.21.160/32` (router) to `auth-acl-main` ## Note This grants query permission only. Reaching the LoadBalancer VIP (198.18.200.6) from off-datacenter paths is separately gated by `externalTrafficPolicy: Local`; the workstation-over-wireguard path still needs its L4 routing addressed to actually land on a node with a ready endpoint. Reviewed-on: #258 Co-authored-by: Ben Vincent <ben@unkin.net> Co-committed-by: Ben Vincent <ben@unkin.net>
This commit was merged in pull request #258.
This commit is contained in:
@@ -24,3 +24,6 @@ spec:
|
|||||||
- 198.18.27.0/24
|
- 198.18.27.0/24
|
||||||
- 198.18.28.0/24
|
- 198.18.28.0/24
|
||||||
- 198.18.29.0/24
|
- 198.18.29.0/24
|
||||||
|
# Admin/management access (individual hosts, not whole subnets)
|
||||||
|
- 10.10.12.200/32 # benvin workstation (wireguard)
|
||||||
|
- 198.18.21.160/32 # benvin router
|
||||||
|
|||||||
Reference in New Issue
Block a user